Assessment Year 1997
Principal Product Expendable and rechargeable lithium cells
NAICS
n/a
SIC 3962:
Sales Range $5
M
to 10
M
# of Employees 200
Plant Area 100,000
ft2
Annual Production 2,500,000
pieces
Production Hrs. Annual 2,500
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $135,756 5,121,043
kWh
Electricity Demand $107,500 11,307
kW-mo/yr
Electricity Fees $7,744 -
Natural Gas $48,069 9,784
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $70,945 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $34,615

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Solid Waste (haz) Savings Personnel Changes Savings
01 4.423: Move product using mechanical means $27,000 $57,660 - - - - $27,000
02 3.5143: Return spent solutions to the manufacturer $16,530 - - - $16,530
-
gal
- -
03 3.1192: Reduce scrap production $11,200 $23,800 - - - $11,200
-
lb
-
04 2.7262: Separate controls of air handlers from ac/ heating systems $7,615 $2,400 $7,615
271,981
kWh
- - - -
05 2.7261: Install timers and/or thermostats $7,500 $2,400 $7,500
267,878
kWh
- - - -
06 2.7122: Disconnect ballasts $1,100 $230 $420
14,947
kWh
$680
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $70,945 $86,490 $15,535
554,806
kWh
$680
-
kW-mo/yr
$16,530
-
gal
$11,200
-
lb
$27,000
TOTAL IMPLEMENTED $34,615 $60,060 $7,615
271,981
kWh
- - - $27,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings Solid Waste (haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs