Assessment Year | 1996 |
---|---|
Principal Product | Packaged country hams |
NAICS |
n/a
|
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $5 M to 10M |
# of Employees | 55 |
Plant Area |
28,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $22,230 | 1,246,776 |
kWh
|
$0.018 |
Electricity Demand | $9,685 | 1,116 |
kW-mo/yr
|
$8.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $160,873 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,594 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.321: Optimize production lot sizes and inventories | $92,395 | $100,000 | - | - | - | $(-7,605.0) | - | - | $100,000 | |
02 | 2.4325: Upgrade conveyors | $30,420 | $14,000 | - | - | - | $30,420 | - | - | - | |
03 | 3.5313: Increase amount of waste recovered for resale | $25,513 | $10,000 | - | - |
$23,721
-
lb
|
- | $1,792 | - | - | |
04 | 4.211: Consider use / purchase of bulk materials where possible | $6,872 | $25,000 | - | - |
$375
-
lb
|
- | - | $6,497 | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $2,668 | - |
$1,021
24,912
kWh
|
$1,647
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 3.6192: Use a less expensive method of waste removal | $1,506 | - | - | - | - | - | $1,506 | - | - | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $821 | $3,000 |
$409
9,965
kWh
|
$412
-
kW-mo/yr
|
- | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $678 | $713 |
$60
1,465
kWh
|
$618
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $160,873 | $152,713 |
$1,490
36,342
kWh
|
$2,677
-
kW-mo/yr
|
$24,096
-
lb
|
$22,815 | $3,298 | $6,497 | $100,000 | ||
TOTAL IMPLEMENTED | $34,594 | $14,000 |
$1,021
24,912
kWh
|
$1,647
-
kW-mo/yr
|
- | $30,420 | $1,506 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs