| Assessment Year | 1997 |
|---|---|
| Principal Product | Radial Tires |
| NAICS |
n/a
|
| SIC | 3011: Tires and Inner Tubes |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
65,000
ft2
|
| Annual Production | 182,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $116,436 | 1,285,756 |
kWh
|
$0.091 |
| Electricity Demand | $40,535 | 3,545 |
kW-mo/yr
|
$11.43 |
| Electricity Fees | $33,242 | - |
|
- |
| Natural Gas | $79,186 | 9,526 |
MMBtu
|
$8.31 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $114,099 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,080 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,285 | $20,912 |
$8,280
91,442
kWh
|
$2,005
-
kW-mo/yr
|
- | - | - | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,204 | $800 |
$969
10,844
kWh
|
$235
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $4,870 | $1,550 | - | - |
$4,870
-
MMBtu
|
- | - | - | - | |
| 04 | 4.423: Move product using mechanical means | $62,400 | $160,000 | - | - | - | - | $62,400 | - | - | |
| 05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $4,140 | $6,500 | - | - | - |
$4,140
-
lb
|
- | - | - | |
| 06 | 3.1121: Use more efficient adhesive applicators | $3,120 | $2,000 | - | - | - | - | - | $3,120 | - | |
| 07 | 3.5218: Reuse / recycle/ sell rubber products | $28,080 | $500 | - | - | - | - | - | - | $28,080 | |
| TOTAL RECOMMENDED | $114,099 | $192,262 |
$9,249
102,286
kWh
|
$2,240
-
kW-mo/yr
|
$4,870
-
MMBtu
|
$4,140
-
lb
|
$62,400 | $3,120 | $28,080 | ||
| TOTAL IMPLEMENTED | $28,080 | $500 | - | - | - | - | - | - | $28,080 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs