Assessment Year | 1996 |
---|---|
Principal Product | Automotive high-pressure flexible hose connectors |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 388 |
Plant Area |
75,000
ft2
|
Annual Production | 6,000,000
pieces
|
Production Hrs. Annual | 5,760
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,288 | 4,011,723 |
kWh
|
$0.029 |
Electricity Demand | $86,317 | 9,030 |
kW-mo/yr
|
$9.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $83,019 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $75,383 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.8211: Convert to aqueous cleaning system | $34,986 | $10,700 | - | - | - |
$(-1,100.0)
-
gal
|
$36,086
-
gal
|
- | - | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $26,602 | $13,880 |
$11,230
320,926
kWh
|
$24,346
-
kW-mo/yr
|
$(-8,974.0)
-
MMBtu
|
- | - | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $13,795 | $13,800 |
$3,765
107,562
kWh
|
$13,030
-
kW-mo/yr
|
$(-3,000.0)
-
MMBtu
|
- | - | - | - | |
04 | 2.2437: Recover waste heat from equipment | $2,810 | $11,100 |
$2,810
80,305
kWh
|
- | - | - | - | - | - | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $2,810 | $8,400 |
$2,810
80,305
kWh
|
- | - | - | - | - | - | |
06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,739 | $5,200 |
$(-500.0)
(-14,361)
kWh
|
- | - | - | - |
$2,739
-
lb
|
$(-500.0) | |
07 | 2.7124: Make a practice of turning off lights when not needed | $277 | - |
$277
7,913
kWh
|
- | - | - | - | - | - | |
TOTAL RECOMMENDED | $83,019 | $63,080 |
$20,392
582,650
kWh
|
$37,376
-
kW-mo/yr
|
$(-11,974.0)
-
MMBtu
|
$(-1,100.0)
-
gal
|
$36,086
-
gal
|
$2,739
-
lb
|
$(-500.0) | ||
TOTAL IMPLEMENTED | $75,383 | $38,380 |
$14,995
428,488
kWh
|
$37,376
-
kW-mo/yr
|
$(-11,974.0)
-
MMBtu
|
$(-1,100.0)
-
gal
|
$36,086
-
gal
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs