| Assessment Year | 1995 |
|---|---|
| Principal Product | Gas-fired and electric pool heaters |
| NAICS |
n/a
|
| SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
65,000
ft2
|
| Annual Production | 25,000
pieces
|
| Production Hrs. Annual | 3,213
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $71,217 | 1,247,948 |
kWh
|
$0.057 |
| Natural Gas | $24,085 | 3,931 |
MMBtu
|
$6.13 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,563 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,334 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $3,355 | $2,320 |
$1,952
65,064
kWh
|
$1,403
-
MMBtu
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $805 | $2,200 | - |
$805
-
MMBtu
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,689 | - |
$2,689
35,463
kWh
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $818 | $620 |
$818
27,257
kWh
|
- | - | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $229 | $385 |
$229
7,620
kWh
|
- | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $349 | $490 |
$349
4,396
kWh
|
- | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $323 | $435 |
$323
3,517
kWh
|
- | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $586 | $442 |
$586
7,327
kWh
|
- | - | |
| 09 | 2.8113: Purchase gas directly from a contract gas supplier | $2,409 | - | - | - | $2,409 | |
| TOTAL RECOMMENDED | $11,563 | $6,892 |
$6,946
150,644
kWh
|
$2,208
-
MMBtu
|
$2,409 | ||
| TOTAL IMPLEMENTED | $11,334 | $6,507 |
$6,717
143,024
kWh
|
$2,208
-
MMBtu
|
$2,409 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs