Assessment Year | 1994 |
---|---|
Principal Product | Children's Apparel |
NAICS |
n/a
|
SIC | 2361: Girls', Children's, and Infants' Dresses, Blouses, and Shirts |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
50,400
ft2
|
Annual Production | 400,000
pieces
|
Production Hrs. Annual | 2,938
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,743 | 1,268,464 |
kWh
|
$0.061 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,888 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,214 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7144: Install spectral reflectors / delamp | $3,212 | $480 |
$3,212
48,066
kWh
|
|
02 | 2.6218: Turn off equipment when not in use | $1,341 | - |
$1,341
21,981
kWh
|
|
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $519 | $570 |
$519
8,499
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $375 | $430 |
$375
6,155
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $286 | $318 |
$286
4,689
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $155 | $420 |
$155
4,396
kWh
|
|
TOTAL RECOMMENDED | $5,888 | $2,218 |
$5,888
93,786
kWh
|
||
TOTAL IMPLEMENTED | $5,214 | $1,228 |
$5,214
80,891
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs