| Assessment Year | 1994 |
|---|---|
| Principal Product | Face Brick |
| NAICS |
n/a
|
| SIC | 3251: Brick and Structural Clay Tile |
| Sales Range | $10 M to 50M |
| # of Employees | 78 |
| Plant Area |
88,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $263,541 | 5,351,114 |
kWh
|
$0.049 |
| Natural Gas | $797,733 | 259,832 |
MMBtu
|
$3.07 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,104 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,458 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $13,700 | - |
$13,700
279,601
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,662 | $1,725 |
$3,662
74,736
kWh
|
|
| 03 | 2.7261: Install timers and/or thermostats | $1,106 | $2,100 |
$1,106
22,567
kWh
|
|
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,652 | $1,930 |
$1,652
33,705
kWh
|
|
| 05 | 2.7144: Install spectral reflectors / delamp | $1,309 | $2,928 |
$1,309
24,326
kWh
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $675 | $240 |
$675
13,775
kWh
|
|
| TOTAL RECOMMENDED | $22,104 | $8,923 |
$22,104
448,710
kWh
|
||
| TOTAL IMPLEMENTED | $16,458 | $4,030 |
$16,458
335,873
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs