Assessment Year | 1993 |
---|---|
Principal Product | Candles |
NAICS |
n/a
|
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
600,000
ft2
|
Annual Production | 815,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $171,172 | 4,067,702 |
kWh
|
$0.042 |
Natural Gas | $105,678 | 22,034 |
MMBtu
|
$4.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,302 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,019 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $15,769 | $6,930 |
$726
17,292
kWh
|
$15,043
-
MMBtu
|
|
02 | 2.7144: Install spectral reflectors / delamp | $17,524 | $43,092 |
$17,524
345,838
kWh
|
- | |
03 | 2.2122: Install / repair insulation on condensate lines | $1,522 | $580 | - |
$1,522
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,822 | $2,457 |
$1,822
43,376
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $382 | $170 |
$382
9,086
kWh
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $283 | - |
$283
6,741
kWh
|
- | |
TOTAL RECOMMENDED | $37,302 | $53,229 |
$20,737
422,333
kWh
|
$16,565
-
MMBtu
|
||
TOTAL IMPLEMENTED | $37,019 | $53,229 |
$20,454
415,592
kWh
|
$16,565
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs