| Assessment Year | 1993 |
|---|---|
| Principal Product | Childrens' Apparel |
| NAICS |
n/a
|
| SIC | 2361: Girls', Children's, and Infants' Dresses, Blouses, and Shirts |
| Sales Range | $10 M to 50M |
| # of Employees | 340 |
| Plant Area |
60,800
ft2
|
| Annual Production | 3,600,000
pieces
|
| Production Hrs. Annual | 3,300
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $80,366 | 1,656,506 |
kWh
|
$0.049 |
| Natural Gas | $36,066 | 6,414 |
MMBtu
|
$5.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,134 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,436 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,894 | $1,500 | - |
$4,894
-
MMBtu
|
|
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $7,339 | $480 |
$7,339
124,267
kWh
|
- | |
| 03 | 2.7144: Install spectral reflectors / delamp | $6,425 | $17,573 |
$6,425
124,267
kWh
|
- | |
| 04 | 2.2135: Repair and eliminate steam leaks | $1,551 | $285 | - |
$1,551
-
MMBtu
|
|
| 05 | 2.2163: Use minimum steam operating pressure | $1,238 | - | - |
$1,238
-
MMBtu
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $876 | $775 |
$876
17,878
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $776 | $841 |
$776
15,826
kWh
|
- | |
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $460 | $410 |
$460
9,379
kWh
|
- | |
| 09 | 2.4314: Use synthetic lubricant | $345 | - |
$345
7,034
kWh
|
- | |
| 10 | 2.4221: Install compressor air intakes in coolest locations | $230 | $490 |
$230
4,689
kWh
|
- | |
| TOTAL RECOMMENDED | $24,134 | $22,354 |
$16,451
303,340
kWh
|
$7,683
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $15,436 | $3,881 |
$8,991
157,971
kWh
|
$6,445
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs