| Plant Area |
n/a
|
| Annual Production | 1,000,000,000
pieces
|
| Production Hrs. Annual | 6,150
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $37,481 | 587,339 |
kWh
|
$0.064 |
| Natural Gas | $18,055 | 3,527 |
MMBtu
|
$5.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,038 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,388 | $800 |
$1,388
21,688
kWh
|
|
| 02 | 2.2511: Insulate bare equipment | $1,200 | $402 |
$1,200
18,757
kWh
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $225 | - |
$225
3,517
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $225 | $670 |
$225
3,517
kWh
|
|
| TOTAL RECOMMENDED | $3,038 | $1,872 |
$3,038
47,479
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs