| Assessment Year | 1991 |
|---|---|
| Principal Product | UNFINISHED CABINET DOORS |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $5 M to 10M |
| # of Employees | 115 |
| Plant Area |
n/a
|
| Annual Production | 750,000
pieces
|
| Production Hrs. Annual | 4,875
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $283,193 | 4,868,992 |
kWh
|
$0.058 |
| Wood | $11,930 | 882,360 |
MMBtu
|
$0.014 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $120,928 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $112,175 | $326,250 |
$115,175
1,207,503
kWh
|
$(-3,000.0)
-
MMBtu
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,324 | $7,500 |
$6,324
109,027
kWh
|
- | |
| 03 | 2.4312: Improve lubrication practices | $595 | $225 |
$595
10,258
kWh
|
- | |
| 04 | 2.6232: Install set-back timers | $476 | - |
$476
8,206
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,358 | $1,564 |
$1,358
33,411
kWh
|
- | |
| TOTAL RECOMMENDED | $120,928 | $335,539 |
$123,928
1,368,405
kWh
|
$(-3,000.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs