Assessment Year 1990
Principal Product PHOTO ENLARGERS
NAICS
n/a
SIC 3861: Photographic Equipment and Supplies
Sales Range $1
M
to 5
M
# of Employees 50
Plant Area
n/a
Annual Production 150
pieces
Production Hrs. Annual 2,444
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $27,594 424,971
kWh
Natural Gas $2,893 524
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $12,203 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,366

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7123: Keep lamps and reflectors clean $4,123 $11,116 $3,962
60,961
kWh
- $161
02 2.7261: Install timers and/or thermostats $2,474 $4,140 $1,847
28,429
kWh
$627
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,428 $960 $1,428
21,981
kWh
- -
04 2.7111: Reduce illumination to minimum necessary levels $1,440 - $1,372
21,102
kWh
- $68
05 2.7226: Use computer programs to optimize hvac performance $925 - $925
14,361
kWh
- -
06 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $880 $500 $880
13,482
kWh
- -
07 2.6242: Minimize operation of equipment maintained in standby condition $780 $660 $780
12,016
kWh
- -
08 2.7122: Disconnect ballasts $96 - $96
1,465
kWh
- -
09 2.4312: Improve lubrication practices $57 $30 $57
879
kWh
- -
TOTAL RECOMMENDED $12,203 $17,406 $11,347
174,676
kWh
$627
-
MMBtu
$229
TOTAL IMPLEMENTED $11,366 $16,716 $10,510
161,781
kWh
$627
-
MMBtu
$229
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs