Assessment Year | 2004 |
---|---|
Principal Product | Heat Treated Parts |
NAICS | 332811: Metal Heat Treating |
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 21 |
Plant Area |
25,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,996 | 127,642 |
kWh
|
$0.68 |
Electricity Demand | $38,524 | 7,466 |
kW-mo/yr
|
$5.16 |
Natural Gas | $38,524 | 29,736 |
MMBtu
|
$1.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,834 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,219 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $699 | - |
$975
9,365
kWh
|
- | $(-276.0) | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,368 | $11,810 |
$11,368
109,196
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $1,168 | $1,200 |
$1,168
11,222
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,520 | $13,375 |
$3,520
33,806
kWh
|
- | - | |
05 | 2.3212: Optimize plant power factor | $1,079 | $1,376 | - | $1,079 | - | |
TOTAL RECOMMENDED | $17,834 | $27,761 |
$17,031
163,589
kWh
|
$1,079 | $(-276.0) | ||
TOTAL IMPLEMENTED | $4,219 | $13,375 |
$4,495
43,171
kWh
|
- | $(-276.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs