Assessment Year | 1990 |
---|---|
Principal Product | MOBILE HOMES |
NAICS |
n/a
|
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 220 |
Plant Area |
n/a
|
Annual Production | 2,700
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,917 | 1,398,886 |
kWh
|
$0.082 |
Fuel Oil #2 | $24,373 | 5,600 |
MMBtu
|
$4.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,643 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,396 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $11,814 | $1,500 |
$673
8,206
kWh
|
$11,141
-
MMBtu
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $2,396 | $930 | - |
$2,396
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,211 | $870 |
$2,211
26,964
kWh
|
- | |
04 | 2.4312: Improve lubrication practices | $1,250 | $1,980 |
$1,250
15,240
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $913 | - |
$913
11,137
kWh
|
- | |
06 | 2.6211: Conserve energy by efficient use of vending machines | $601 | $535 |
$601
7,327
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $458 | $380 |
$458
5,569
kWh
|
- | |
TOTAL RECOMMENDED | $19,643 | $6,195 |
$6,106
74,443
kWh
|
$13,537
-
MMBtu
|
||
TOTAL IMPLEMENTED | $15,396 | $2,750 |
$4,255
51,876
kWh
|
$11,141
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs