Assessment Year | 1989 |
---|---|
Principal Product | ELECTRIC CORDS & CABLES |
NAICS |
n/a
|
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $10 M to 50M |
# of Employees | 270 |
Plant Area |
n/a
|
Annual Production | 18,000,000
pieces
|
Production Hrs. Annual | 7,056
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $214,128 | 4,247,069 |
kWh
|
$0.050 |
Fuel Oil #2 | $2,683 | 560 |
MMBtu
|
$4.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,658 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,012 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7123: Keep lamps and reflectors clean | $12,907 | $20,156 |
$11,899
237,984
kWh
|
- | $1,008 | |
02 | 2.7261: Install timers and/or thermostats | $6,433 | $560 |
$6,433
128,664
kWh
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,038 | - |
$6,038
120,750
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,235 | $1,050 |
$5,235
104,631
kWh
|
- | - | |
05 | 2.6232: Install set-back timers | $2,752 | - |
$2,752
55,100
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $943 | $243 |
$943
18,757
kWh
|
- | - | |
07 | 2.2511: Insulate bare equipment | $2,374 | $624 |
$2,374
47,479
kWh
|
- | - | |
08 | 2.4312: Improve lubrication practices | $456 | - |
$456
9,086
kWh
|
- | - | |
09 | 2.7314: Reduce ventilation air | $118 | $173 |
$118
2,345
kWh
|
- | - | |
10 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $12,402 | $15,000 |
$21,234
424,678
kWh
|
$(-8,832.0)
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $49,658 | $37,806 |
$57,482
1,149,474
kWh
|
$(-8,832.0)
-
MMBtu
|
$1,008 | ||
TOTAL IMPLEMENTED | $32,012 | $22,009 |
$31,004
619,872
kWh
|
- | $1,008 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs