Assessment Year | 1988 |
---|---|
Principal Product | JUVENILE WOOD PRODUCTS |
NAICS |
n/a
|
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $5 M to 10M |
# of Employees | 195 |
Plant Area |
n/a
|
Annual Production | 152,000
pieces
|
Production Hrs. Annual | 3,163
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $95,857 | 1,126,905 |
kWh
|
$0.085 |
Natural Gas | $37,271 | 7,780 |
MMBtu
|
$4.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,438 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,853 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $1,038 | $18,500 |
$(-2,322.0)
(-27,257)
kWh
|
$3,360
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,104 | $750 |
$13,104
154,162
kWh
|
- | - | |
03 | 2.7123: Keep lamps and reflectors clean | $9,501 | $19,134 |
$9,093
106,975
kWh
|
- | $408 | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $10,015 | $4,840 |
$10,015
117,819
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,400 | - |
$3,400
39,859
kWh
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,943 | $1,220 |
$1,943
22,860
kWh
|
- | - | |
07 | 2.7122: Disconnect ballasts | $1,320 | $2,321 |
$1,320
15,533
kWh
|
- | - | |
08 | 2.4312: Improve lubrication practices | $1,071 | - |
$1,071
12,603
kWh
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,046 | $360 |
$1,046
12,309
kWh
|
- | - | |
TOTAL RECOMMENDED | $42,438 | $47,125 |
$38,670
454,863
kWh
|
$3,360
-
MMBtu
|
$408 | ||
TOTAL IMPLEMENTED | $30,853 | $9,131 |
$30,853
362,836
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs