Assessment Year 1988
Principal Product CUSTOM PACKAGES
NAICS
n/a
SIC 2655: Fiber Cans, Tubes, Drums, and Similar Products
Sales Range $1
M
to 5
M
# of Employees 165
Plant Area
n/a
Annual Production 2,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $42,458 675,557
kWh
LPG $13,915 2,387
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $16,811 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,912

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings LPG Savings Administrative Changes Savings
01 2.7123: Keep lamps and reflectors clean $9,080 $21,056 $8,918
141,559
kWh
- $162
02 2.7121: Utilize daylight whenever possible in lieu of artificial light $2,622 $10,214 $2,622
41,618
kWh
- -
03 2.6232: Install set-back timers $1,108 - $1,108
17,585
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,034 $270 $1,034
16,413
kWh
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $812 - $812
12,896
kWh
- -
06 2.7314: Reduce ventilation air $720 $1,000 $720
11,430
kWh
- -
07 2.7446: Utilize sensors controlling roof and wall openings $197 $140 - $197
-
MMBtu
-
08 2.6211: Conserve energy by efficient use of vending machines $351 $520 $351
5,569
kWh
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $314 $135 $314
4,982
kWh
- -
10 2.2511: Insulate bare equipment $314 $121 $314
4,982
kWh
- -
11 2.4312: Improve lubrication practices $259 $240 $259
4,103
kWh
- -
TOTAL RECOMMENDED $16,811 $33,696 $16,452
261,137
kWh
$197
-
MMBtu
$162
TOTAL IMPLEMENTED $4,912 $2,286 $4,912
77,960
kWh
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings LPG Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs