Assessment Year | 1988 |
---|---|
Principal Product | MOUNTED BEARINGS |
NAICS |
n/a
|
SIC | 3562: Ball and Roller Bearings |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
n/a
|
Annual Production | 2,600,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $759,223 | 15,456,917 |
kWh
|
$0.049 |
Natural Gas | $53,458 | 10,180 |
MMBtu
|
$5.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $88,132 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $66,649 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7123: Keep lamps and reflectors clean | $42,911 | $23,701 |
$42,911
875,733
kWh
|
|
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $14,762 | $35,660 |
$14,762
301,290
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,447 | $4,500 |
$14,447
294,842
kWh
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,721 | - |
$6,721
137,163
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,610 | $2,000 |
$4,610
94,080
kWh
|
|
06 | 2.4221: Install compressor air intakes in coolest locations | $3,647 | $780 |
$3,647
74,443
kWh
|
|
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,034 | $1,300 |
$1,034
21,102
kWh
|
|
TOTAL RECOMMENDED | $88,132 | $67,941 |
$88,132
1,798,653
kWh
|
||
TOTAL IMPLEMENTED | $66,649 | $32,281 |
$66,649
1,360,200
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs