| Assessment Year | 1987 |
|---|---|
| Principal Product | ELECTRICAL HEATING ELEMENTS |
| NAICS |
n/a
|
| SIC | 3634: Electric Housewares and Fans |
| Sales Range | $10 M to 50M |
| # of Employees | 275 |
| Plant Area |
n/a
|
| Annual Production | 40,000
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $209,285 | 3,529,895 |
kWh
|
$0.059 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,203 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,456 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $11,914 | - |
$11,914
201,934
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,487 | $520 |
$7,487
126,905
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,055 | $1,200 |
$1,055
17,878
kWh
|
|
| 04 | 2.4312: Improve lubrication practices | $747 | - |
$747
12,603
kWh
|
|
| TOTAL RECOMMENDED | $21,203 | $1,720 |
$21,203
359,320
kWh
|
||
| TOTAL IMPLEMENTED | $20,456 | $1,720 |
$20,456
346,717
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs