| Assessment Year | 1987 |
|---|---|
| Principal Product | TILLAGE IMPLEMENTS-FARM |
| NAICS |
n/a
|
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 68 |
| Plant Area |
n/a
|
| Annual Production | 10,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $46,293 | 661,489 |
kWh
|
$0.070 |
| Natural Gas | $4,423 | 805 |
MMBtu
|
$5.49 |
| Fuel Oil #2 | $19,120 | 3,266 |
MMBtu
|
$5.85 |
| Other Energy | $788 | 107 |
MMBtu
|
$7.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,204 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,204 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,664 | $1,743 | - |
$418
-
MMBtu
|
$1,246
-
MMBtu
|
- | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $397 | - | - | - |
$1,072
-
MMBtu
|
$(-675.0) | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,231 | $150 |
$1,231
17,585
kWh
|
- | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $522 | $3,600 |
$522
7,327
kWh
|
- | - | - | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $390 | - |
$390
5,569
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $4,204 | $5,493 |
$2,143
30,481
kWh
|
$418
-
MMBtu
|
$2,318
-
MMBtu
|
$(-675.0) | ||
| TOTAL IMPLEMENTED | $4,204 | $5,493 |
$2,143
30,481
kWh
|
$418
-
MMBtu
|
$2,318
-
MMBtu
|
$(-675.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs