Assessment Year | 2011 |
---|---|
Principal Product | newpapers |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $50 M to 100M |
# of Employees | 400 |
Plant Area |
150,000
ft2
|
Annual Production | 80,000
ton
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $331,888 | 5,863,120 |
kWh
|
$0.057 |
Electricity Demand | $125,212 | 18,844 |
kW-mo/yr
|
$6.64 |
Electricity Fees | $71,562 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,641 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,717 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $18,841 | $46,645 |
$16,196
284,135
kWh
|
$2,645
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,475 | $1,320 |
$8,040
141,047
kWh
|
$435
-
kW-mo/yr
|
|
03 | 2.7221: Lower temperature during the winter season and vice-versa | $8,367 | $2,550 |
$7,191
126,156
kWh
|
$1,176
-
kW-mo/yr
|
|
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,856 | $9,183 |
$2,457
43,112
kWh
|
$399
-
kW-mo/yr
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,117 | $9,600 |
$1,519
26,646
kWh
|
$598
-
kW-mo/yr
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,875 | $50 |
$1,344
23,576
kWh
|
$531
-
kW-mo/yr
|
|
07 | 2.4322: Use or replace with energy efficient substitutes | $1,858 | $3,943 |
$1,597
28,013
kWh
|
$261
-
kW-mo/yr
|
|
08 | 2.4323: Use optimum size and capacity equipment | $1,252 | $4,571 |
$1,028
18,032
kWh
|
$224
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $45,641 | $77,862 |
$39,372
690,717
kWh
|
$6,269
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $18,717 | $3,920 |
$16,575
290,779
kWh
|
$2,142
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs