| Assessment Year | 2011 |
|---|---|
| Principal Product | newpapers |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2752: Commercial Printing, Lithographic |
| Sales Range | $50 M to 100M |
| # of Employees | 400 |
| Plant Area |
150,000
ft2
|
| Annual Production | 80,000
ton
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $331,888 | 5,863,120 |
kWh
|
$0.057 |
| Electricity Demand | $125,212 | 18,844 |
kW-mo/yr
|
$6.64 |
| Electricity Fees | $71,562 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,641 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,717 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7425: Clean or color roof to reduce solar load | $18,841 | $46,645 |
$16,196
284,135
kWh
|
$2,645
-
kW-mo/yr
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,475 | $1,320 |
$8,040
141,047
kWh
|
$435
-
kW-mo/yr
|
|
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $8,367 | $2,550 |
$7,191
126,156
kWh
|
$1,176
-
kW-mo/yr
|
|
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,856 | $9,183 |
$2,457
43,112
kWh
|
$399
-
kW-mo/yr
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,117 | $9,600 |
$1,519
26,646
kWh
|
$598
-
kW-mo/yr
|
|
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,875 | $50 |
$1,344
23,576
kWh
|
$531
-
kW-mo/yr
|
|
| 07 | 2.4322: Use or replace with energy efficient substitutes | $1,858 | $3,943 |
$1,597
28,013
kWh
|
$261
-
kW-mo/yr
|
|
| 08 | 2.4323: Use optimum size and capacity equipment | $1,252 | $4,571 |
$1,028
18,032
kWh
|
$224
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $45,641 | $77,862 |
$39,372
690,717
kWh
|
$6,269
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $18,717 | $3,920 |
$16,575
290,779
kWh
|
$2,142
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs