| Assessment Year | 1987 |
|---|---|
| Principal Product | GAS & ELECTRIC RANGE COMPONENTS |
| NAICS |
n/a
|
| SIC | 3631: Household Cooking Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $605,190 | 12,436,987 |
kWh
|
$0.049 |
| Natural Gas | $196,173 | 39,742 |
MMBtu
|
$4.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $220,623 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $219,387 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $11,719 | - |
$11,719
239,156
kWh
|
- | |
| 02 | 2.2511: Insulate bare equipment | $7,037 | $1,200 |
$7,037
143,611
kWh
|
- | |
| 03 | 2.2511: Insulate bare equipment | $1,769 | $1,904 | - |
$1,769
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,973 | $780 |
$3,973
81,184
kWh
|
- | |
| 05 | 2.2163: Use minimum steam operating pressure | $741 | - | - |
$741
-
MMBtu
|
|
| 06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $948 | $3,960 |
$948
19,343
kWh
|
- | |
| 07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $272 | $250 | - |
$272
-
MMBtu
|
|
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,815 | $720 |
$2,815
57,444
kWh
|
- | |
| 09 | 2.4239: Eliminate or reduce compressed air usage | $661 | $348 |
$661
13,482
kWh
|
- | |
| 10 | 2.2136: Install / repair insulation on steam lines | $124 | $231 | - |
$124
-
MMBtu
|
|
| 11 | 2.2122: Install / repair insulation on condensate lines | $99 | $62 | - |
$99
-
MMBtu
|
|
| 12 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $174,746 | $36,800 |
$304,699
6,218,347
kWh
|
$(-129,953.0)
-
MMBtu
|
|
| 13 | 2.2447: Heat water with exhaust heat | $15,719 | $26,500 | - |
$15,719
-
MMBtu
|
|
| TOTAL RECOMMENDED | $220,623 | $72,755 |
$331,852
6,772,567
kWh
|
$(-111,229.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $219,387 | $72,212 |
$331,852
6,772,567
kWh
|
$(-112,465.0)
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs