Assessment Year 1987
Principal Product GAS & ELECTRIC RANGE COMPONENTS
NAICS
n/a
SIC 3631: Household Cooking Equipment
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area
n/a
Annual Production 5,000,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $605,190 12,436,987
kWh
Natural Gas $196,173 39,742
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $220,623 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $219,387

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6232: Install set-back timers $11,719 - $11,719
239,156
kWh
-
02 2.2511: Insulate bare equipment $7,037 $1,200 $7,037
143,611
kWh
-
03 2.2511: Insulate bare equipment $1,769 $1,904 - $1,769
-
MMBtu
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,973 $780 $3,973
81,184
kWh
-
05 2.2163: Use minimum steam operating pressure $741 - - $741
-
MMBtu
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $948 $3,960 $948
19,343
kWh
-
07 2.1233: Analyze flue gas for proper air/fuel ratio $272 $250 - $272
-
MMBtu
08 2.7142: Utilize higher efficiency lamps and/or ballasts $2,815 $720 $2,815
57,444
kWh
-
09 2.4239: Eliminate or reduce compressed air usage $661 $348 $661
13,482
kWh
-
10 2.2136: Install / repair insulation on steam lines $124 $231 - $124
-
MMBtu
11 2.2122: Install / repair insulation on condensate lines $99 $62 - $99
-
MMBtu
12 2.1311: Replace electrically-operated equipment with fossil fuel equipment $174,746 $36,800 $304,699
6,218,347
kWh
$(-129,953.0)
-
MMBtu
13 2.2447: Heat water with exhaust heat $15,719 $26,500 - $15,719
-
MMBtu
TOTAL RECOMMENDED $220,623 $72,755 $331,852
6,772,567
kWh
$(-111,229.0)
-
MMBtu
TOTAL IMPLEMENTED $219,387 $72,212 $331,852
6,772,567
kWh
$(-112,465.0)
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs