| Assessment Year | 1987 |
|---|---|
| Principal Product | CONSUMER APPLIANCE PARTS |
| NAICS |
n/a
|
| SIC | 3634: Electric Housewares and Fans |
| Sales Range | $10 M to 50M |
| # of Employees | 103 |
| Plant Area |
n/a
|
| Annual Production | 7,000,000
pieces
|
| Production Hrs. Annual | 4,335
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $35,794 | 591,735 |
kWh
|
$0.060 |
| Natural Gas | $20,061 | 3,654 |
MMBtu
|
$5.49 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,152 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,832 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $1,386 | $6,000 |
$(-270.0)
(-4,396)
kWh
|
$1,656
-
MMBtu
|
|
| 02 | 2.6214: Shut off pilots in standby equipment | $1,628 | - | - |
$1,628
-
MMBtu
|
|
| 03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $3,200 | $400 |
$3,200
53,341
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,618 | $75 |
$1,618
26,964
kWh
|
- | |
| 05 | 2.6232: Install set-back timers | $320 | $445 |
$320
5,275
kWh
|
- | |
| TOTAL RECOMMENDED | $8,152 | $6,920 |
$4,868
81,184
kWh
|
$3,284
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,832 | $6,475 |
$4,548
75,909
kWh
|
$3,284
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs