| Assessment Year | 1985 |
|---|---|
| Principal Product | SMALL KITCHEN APPLIANCES |
| NAICS |
n/a
|
| SIC | 3634: Electric Housewares and Fans |
| Sales Range | $10 M to 50M |
| # of Employees | 400 |
| Plant Area |
n/a
|
| Annual Production | 1,500,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $435,511 | 10,415,006 |
kWh
|
$0.042 |
| Natural Gas | $15,790 | 2,721 |
MMBtu
|
$5.80 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,975 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $7,624 | $1,400 |
$9,747
233,001
kWh
|
$(-2,123.0)
-
MMBtu
|
|
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $8,827 | $4,000 |
$8,827
211,020
kWh
|
- | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $6,044 | $13,200 |
$3,678
87,925
kWh
|
$2,366
-
MMBtu
|
|
| 04 | 2.2692: Use outside cold water source as a supply of cooling water | $5,480 | $12,000 |
$5,480
131,008
kWh
|
- | |
| TOTAL RECOMMENDED | $27,975 | $30,600 |
$27,732
662,954
kWh
|
$243
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs