| Assessment Year | 1986 |
|---|---|
| Principal Product | WORK PANTS |
| NAICS |
n/a
|
| SIC | 2326: Men's and Boys' Work Clothing |
| Sales Range | $500 k to 1M |
| # of Employees | 375 |
| Plant Area |
n/a
|
| Annual Production | 2,419,200
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $92,965 | 1,300,997 |
kWh
|
$0.071 |
| Natural Gas | $33,403 | 7,052 |
MMBtu
|
$4.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,179 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,979 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7262: Separate controls of air handlers from ac/ heating systems | $8,544 | $9,080 |
$8,544
119,578
kWh
|
- | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $1,673 | $3,100 | - |
$1,673
-
MMBtu
|
|
| 03 | 2.2437: Recover waste heat from equipment | $948 | $1,885 | - |
$948
-
MMBtu
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $3,162 | - |
$3,162
44,256
kWh
|
- | |
| 05 | 2.1222: Install turbulators | $469 | $500 | - |
$469
-
MMBtu
|
|
| 06 | 2.2122: Install / repair insulation on condensate lines | $90 | $50 | - |
$90
-
MMBtu
|
|
| 07 | 2.6242: Minimize operation of equipment maintained in standby condition | $293 | $500 |
$293
4,103
kWh
|
- | |
| TOTAL RECOMMENDED | $15,179 | $15,115 |
$11,999
167,937
kWh
|
$3,180
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,979 | $13,180 |
$8,837
123,681
kWh
|
$2,142
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs