Assessment Year | 2000 |
---|---|
Principal Product | Audio/Video cables |
NAICS |
n/a
|
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $50 M to 100M |
# of Employees | 620 |
Plant Area |
220,000
ft2
|
Annual Production | 30,000
units
|
Production Hrs. Annual | 4,550
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $216,153 | 2,431,200 |
kWh
|
$0.089 |
Natural Gas | $28,488 | 4,903 |
MMBtu
|
$5.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,995 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,619 | $2,800 |
$2,307
28,665
kWh
|
$312
-
kW-mo/yr
|
- | |
02 | 2.7132: Install timers on light switches in little used areas | $2,726 | $7,750 |
$2,402
29,846
kWh
|
$324
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,122 | $13,280 |
$3,615
44,919
kWh
|
$507
-
kW-mo/yr
|
- | |
04 | 3.5311: Recover and reuse waste material | $24,800 | - | - | - |
$24,800
-
lb
|
|
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $16,728 | $70,000 | - | - |
$16,728
-
lb
|
|
TOTAL RECOMMENDED | $50,995 | $93,830 |
$8,324
103,430
kWh
|
$1,143
-
kW-mo/yr
|
$41,528
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs