Assessment Year | 1986 |
---|---|
Principal Product | LIGHT BULBS FOR CARS |
NAICS |
n/a
|
SIC | 3641: Electric Lamp Bulbs and Tubes |
Sales Range | $10 M to 50M |
# of Employees | 544 |
Plant Area |
n/a
|
Annual Production | 300,000,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $368,628 | 7,321,806 |
kWh
|
$0.050 |
Natural Gas | $88,175 | 15,761 |
MMBtu
|
$5.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,821 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,339 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7492: Use proper thickness of insulation on building envelope | $13,106 | $39,200 |
$10,654
211,606
kWh
|
$2,452
-
MMBtu
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,570 | $4,000 |
$7,570
150,352
kWh
|
- | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,285 | - |
$6,285
124,853
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,223 | - |
$4,223
83,822
kWh
|
- | |
05 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,339 | - |
$3,339
66,237
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $2,298 | $648 |
$2,298
45,721
kWh
|
- | |
TOTAL RECOMMENDED | $36,821 | $43,848 |
$34,369
682,591
kWh
|
$2,452
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,339 | - |
$3,339
66,237
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs