Assessment Year | 1986 |
---|---|
Principal Product | WOMEN'S HANDBAGS |
NAICS |
n/a
|
SIC | 3171: Women's Handbags and Purses |
Sales Range | $5 M to 10M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 750,000
pieces
|
Production Hrs. Annual | 2,470
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,857 | 466,882 |
kWh
|
$0.068 |
Natural Gas | $21,650 | 3,977 |
MMBtu
|
$5.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,325 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,325 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $2,310 | $1,500 |
$(-40.0)
(-586)
kWh
|
$2,350
-
MMBtu
|
|
02 | 2.7243: Improve air circulation with destratification fans / other methods | $1,414 | $1,800 | - |
$1,414
-
MMBtu
|
|
03 | 2.6232: Install set-back timers | $2,001 | - |
$2,001
29,308
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $680 | - |
$680
9,965
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $920 | $288 |
$920
13,482
kWh
|
- | |
TOTAL RECOMMENDED | $7,325 | $3,588 |
$3,561
52,169
kWh
|
$3,764
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,325 | $3,588 |
$3,561
52,169
kWh
|
$3,764
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs