| Assessment Year | 1986 |
|---|---|
| Principal Product | ADULT & CHILDREN CLOTHES |
| NAICS |
n/a
|
| SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
| Sales Range | $10 M to 50M |
| # of Employees | 500 |
| Plant Area |
n/a
|
| Annual Production | 2,000,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $43,454 | 720,985 |
kWh
|
$0.060 |
| LPG | $117,232 | 21,695 |
MMBtu
|
$5.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,398 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,269 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2515: Use optimum thickness insulation | $2,008 | $2,000 |
$2,008
81,770
kWh
|
- | - | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $884 | - | - |
$1,184
-
MMBtu
|
$(-300.0) | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,482 | $250 |
$3,482
58,030
kWh
|
- | - | |
| 04 | 2.2122: Install / repair insulation on condensate lines | $895 | $250 | - |
$895
-
MMBtu
|
- | |
| 05 | 2.2122: Install / repair insulation on condensate lines | $529 | $200 | - |
$529
-
MMBtu
|
- | |
| 06 | 2.6232: Install set-back timers | $1,600 | - |
$1,600
26,671
kWh
|
- | - | |
| TOTAL RECOMMENDED | $9,398 | $2,700 |
$7,090
166,471
kWh
|
$2,608
-
MMBtu
|
$(-300.0) | ||
| TOTAL IMPLEMENTED | $7,269 | $2,500 |
$5,490
139,800
kWh
|
$2,079
-
MMBtu
|
$(-300.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs