Assessment Year 1985
Principal Product WORSTEN KNITTING YARNS
NAICS
n/a
SIC 2281: Yarn Spinning Mills
Sales Range $50
M
to 100
M
# of Employees 480
Plant Area
n/a
Annual Production 17,000,000
lb
Production Hrs. Annual 0
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $559,623 16,658,558
kWh
Natural Gas $141,143 23,776
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $52,171 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,777

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2437: Recover waste heat from equipment $31,022 $59,300 - $31,022
-
MMBtu
02 2.2223: Enhance sensitivity of temperature control and cutoff $13,198 $565 - $13,198
-
MMBtu
03 2.4231: Reduce the pressure of compressed air to the minimum required $3,946 $1,000 $3,946
119,578
kWh
-
04 2.7111: Reduce illumination to minimum necessary levels $2,582 - $2,582
78,253
kWh
-
05 2.2122: Install / repair insulation on condensate lines $997 $108 - $997
-
MMBtu
06 2.4221: Install compressor air intakes in coolest locations $426 $220 $426
12,896
kWh
-
TOTAL RECOMMENDED $52,171 $61,193 $6,954
210,727
kWh
$45,217
-
MMBtu
TOTAL IMPLEMENTED $16,777 $673 $2,582
78,253
kWh
$14,195
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs