Assessment Year | 1985 |
---|---|
Principal Product | VALVES FOR CHEMICAL PROC |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 4,704
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $398,806 | 8,211,899 |
kWh
|
$0.049 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,202 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,048 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7234: Use heat pump for space conditioning | $17,233 | $429,000 |
$17,233
351,700
kWh
|
|
02 | 2.7243: Improve air circulation with destratification fans / other methods | $8,904 | $37,200 |
$8,904
181,712
kWh
|
|
03 | 2.2514: Cover open tanks | $3,102 | $200 |
$3,102
63,306
kWh
|
|
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,915 | - |
$2,915
59,496
kWh
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $1,048 | $450 |
$1,048
21,395
kWh
|
|
TOTAL RECOMMENDED | $33,202 | $466,850 |
$33,202
677,609
kWh
|
||
TOTAL IMPLEMENTED | $1,048 | $450 |
$1,048
21,395
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs