Assessment Year | 1985 |
---|---|
Principal Product | MEN'S & WOMEN'S CLOTHES |
NAICS |
n/a
|
SIC | 2311: Men's and Boys' Suits, Coats, and Overcoats |
Sales Range | $1 M to 5M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $54,961 | 890,387 |
kWh
|
$0.062 |
Natural Gas | $11,336 | 1,895 |
MMBtu
|
$5.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,491 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,628 | $375 |
$1,628
26,377
kWh
|
- | |
02 | 2.6232: Install set-back timers | $380 | - |
$380
6,155
kWh
|
- | |
03 | 2.2136: Install / repair insulation on steam lines | $102 | $119 | - |
$102
-
MMBtu
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $327 | $420 |
$327
5,275
kWh
|
- | |
05 | 2.2122: Install / repair insulation on condensate lines | $54 | $40 | - |
$54
-
MMBtu
|
|
TOTAL RECOMMENDED | $2,491 | $954 |
$2,335
37,807
kWh
|
$156
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs