| Assessment Year | 1985 |
|---|---|
| Principal Product | RR MAINTENANCE EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3531: Construction Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 200,000
lb
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $77,715 | 1,412,954 |
kWh
|
$0.055 |
| Natural Gas | $36,222 | 6,646 |
MMBtu
|
$5.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,274 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,586 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,237 | $180 |
$9,237
167,937
kWh
|
- | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $8,060 | - |
$8,060
146,542
kWh
|
- | |
| 03 | 2.7261: Install timers and/or thermostats | $2,349 | $300 | - |
$2,349
-
MMBtu
|
|
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,628 | - |
$2,628
47,773
kWh
|
- | |
| TOTAL RECOMMENDED | $22,274 | $480 |
$19,925
362,252
kWh
|
$2,349
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,586 | $480 |
$9,237
167,937
kWh
|
$2,349
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs