Assessment Year | 1983 |
---|---|
Principal Product | HEAT TRANSFER EQUIPMENT |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 105 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $78,054 | 1,197,245 |
kWh
|
$0.065 |
Natural Gas | $60,805 | 11,410 |
MMBtu
|
$5.33 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,497 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $11,000 | $53,000 | - |
$11,000
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,977 | $4,000 |
$8,977
137,749
kWh
|
- | |
03 | 2.6232: Install set-back timers | $520 | - |
$520
8,792
kWh
|
- | |
TOTAL RECOMMENDED | $20,497 | $57,000 |
$9,497
146,541
kWh
|
$11,000
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs