| Assessment Year | 1982 |
|---|---|
| Principal Product | GRAY IRON FOUNDRIES |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
n/a
|
| Annual Production | 1,500
ton
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $83,185 | 1,409,730 |
kWh
|
$0.059 |
| Natural Gas | $83,630 | 15,596 |
MMBtu
|
$5.36 |
| Other Energy | $60,759 | 9,336 |
MMBtu
|
$6.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,560 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $11,700 | $30,000 | - | - |
$11,700
-
MMBtu
|
|
| 02 | 2.7261: Install timers and/or thermostats | $5,940 | - | - |
$5,940
-
MMBtu
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,620 | - |
$2,620
87,339
kWh
|
- | - | |
| TOTAL RECOMMENDED | $20,260 | $30,000 |
$2,620
87,339
kWh
|
$5,940
-
MMBtu
|
$11,700
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,560 | - |
$2,620
87,339
kWh
|
$5,940
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs