Assessment Year | 1982 |
---|---|
Principal Product | UNDERWEAR |
NAICS |
n/a
|
SIC | 2322: Men's and Boys' Underwear and Nightwear |
Sales Range | $10 M to 50M |
# of Employees | 430 |
Plant Area |
n/a
|
Annual Production | 12,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $136,907 | 3,267,585 |
kWh
|
$0.042 |
LPG | $185,438 | 29,047 |
MMBtu
|
$6.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,874 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $6,284 | - |
$6,284
235,053
kWh
|
|
02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $4,900 | - |
$4,900
183,177
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,430 | - |
$2,430
90,856
kWh
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,260 | $17,250 |
$1,260
19,050
kWh
|
|
TOTAL RECOMMENDED | $14,874 | $17,250 |
$14,874
528,136
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs