| Assessment Year | 2006 |
|---|---|
| Principal Product | Forging Die-Tools |
| NAICS | 333514: Special Die and Tool, Die Set, Jig, and Fixture Manufacturing |
| SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
| Sales Range | $1 M to 5M |
| # of Employees | 13 |
| Plant Area |
11,200
ft2
|
| Annual Production | 400
units
|
| Production Hrs. Annual | 2,569
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $17,357 | 135,264 |
kWh
|
$0.13 |
| Electricity Demand | $6,551 | 922 |
kW-mo/yr
|
$7.11 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $64,567 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,981 | $1,440 |
$3,164
24,722
kWh
|
$817
-
kW-mo/yr
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,627 | $1,030 |
$2,208
17,253
kWh
|
$419
-
kW-mo/yr
|
|
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $52,032 | $10,650 |
$52,032
406,502
kWh
|
- | |
| 04 | 2.7442: Keep doors and windows shut when not on use | $5,927 | - |
$5,927
46,307
kWh
|
- | |
| TOTAL RECOMMENDED | $64,567 | $13,120 |
$63,331
494,784
kWh
|
$1,236
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs