Assessment Year | 2005 |
---|---|
Principal Product | Plastic Airplane Parts |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 100 |
Plant Area |
260,000
ft2
|
Annual Production | 30,000
pieces
|
Production Hrs. Annual | 6,192
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $520,493 | 4,574,626 |
kWh
|
$0.11 |
Electricity Demand | $133,879 | 23,403 |
kW-mo/yr
|
$5.72 |
Natural Gas | $108,775 | 15,628 |
MMBtu
|
$6.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,412 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,072 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $34,650 | - |
$34,650
456,529
kWh
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $2,356 | - |
$2,356
31,045
kWh
|
- | - | |
03 | 2.6218: Turn off equipment when not in use | $4,666 | - |
$3,873
52,346
kWh
|
$793
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,400 | $1,440 |
$7,360
97,004
kWh
|
$1,040
-
kW-mo/yr
|
- | |
05 | 2.4239: Eliminate or reduce compressed air usage | $680 | - |
$280
3,695
kWh
|
$400
-
kW-mo/yr
|
- | |
06 | 2.4226: Use / purchase optimum sized compressor | $1,990 | - |
$880
11,548
kWh
|
$120
-
kW-mo/yr
|
$990 | |
07 | 2.4221: Install compressor air intakes in coolest locations | $4,670 | $980 |
$4,091
53,912
kWh
|
$579
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $57,412 | $2,420 |
$53,490
706,079
kWh
|
$2,932
-
kW-mo/yr
|
$990 | ||
TOTAL IMPLEMENTED | $50,072 | $1,440 |
$48,239
636,924
kWh
|
$1,833
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs