| Assessment Year | 2005 |
|---|---|
| Principal Product | Plastic Canopies |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
35,000
ft2
|
| Annual Production | 3,000
pieces
|
| Production Hrs. Annual | 4,449
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $458,473 | 6,042,125 |
kWh
|
$0.076 |
| Electricity Demand | $130,773 | 23,944 |
kW-mo/yr
|
$5.46 |
| Natural Gas | $336,169 | 43,354 |
MMBtu
|
$7.75 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,817 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $41,797 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $7,070 | - |
$7,070
93,200
kWh
|
|
| 02 | 2.7442: Keep doors and windows shut when not on use | $22,990 | - |
$22,990
302,930
kWh
|
|
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,020 | $1,880 |
$3,020
39,742
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,491 | $241 |
$3,491
41,823
kWh
|
|
| 05 | 2.4239: Eliminate or reduce compressed air usage | $1,785 | $1,444 |
$1,785
23,530
kWh
|
|
| 06 | 2.7135: Install occupancy sensors | $6,461 | $244 |
$6,461
66,205
kWh
|
|
| TOTAL RECOMMENDED | $44,817 | $3,809 |
$44,817
567,430
kWh
|
||
| TOTAL IMPLEMENTED | $41,797 | $1,929 |
$41,797
527,688
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs