Assessment Year 2005
Principal Product Plastic Canopies
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 35,000
ft2
Annual Production 3,000
pieces
Production Hrs. Annual 4,449
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $458,473 6,042,125
kWh
Electricity Demand $130,773 23,944
kW-mo/yr
Natural Gas $336,169 43,354
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $44,817 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $41,797

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7221: Lower temperature during the winter season and vice-versa $7,070 - $7,070
93,200
kWh
02 2.7442: Keep doors and windows shut when not on use $22,990 - $22,990
302,930
kWh
03 2.7447: Install vinyl strip / high speed / air curtain doors $3,020 $1,880 $3,020
39,742
kWh
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,491 $241 $3,491
41,823
kWh
05 2.4239: Eliminate or reduce compressed air usage $1,785 $1,444 $1,785
23,530
kWh
06 2.7135: Install occupancy sensors $6,461 $244 $6,461
66,205
kWh
TOTAL RECOMMENDED $44,817 $3,809 $44,817
567,430
kWh
TOTAL IMPLEMENTED $41,797 $1,929 $41,797
527,688
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs