| Assessment Year | 2005 |
|---|---|
| Principal Product | Blowers and Fans |
| NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
| SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 136 |
| Plant Area |
78,000
ft2
|
| Annual Production | 3,000,000
pieces
|
| Production Hrs. Annual | 6,048
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $132,315 | 2,333,610 |
kWh
|
$0.057 |
| Electricity Demand | $36,085 | 5,496 |
kW-mo/yr
|
$6.57 |
| Natural Gas | $4,835 | 728 |
MMBtu
|
$6.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $39,515 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,300 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.111: Add equipment/ operators to reduce production bottleneck | $17,820 | $1,035 | - | - | $17,820 | |
| 02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $9,270 | $2,660 |
$9,270
163,509
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,300 | $530 |
$4,300
75,360
kWh
|
$1,000
-
kW-mo/yr
|
- | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,440 | $2,000 |
$2,440
43,204
kWh
|
- | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,615 | - |
$1,260
15,962
kWh
|
$355
-
kW-mo/yr
|
- | |
| 06 | 2.6242: Minimize operation of equipment maintained in standby condition | $270 | - | - |
$270
-
kW-mo/yr
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,370 | - |
$1,930
34,000
kWh
|
$440
-
kW-mo/yr
|
- | |
| 08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $430 | - |
$430
7,550
kWh
|
- | - | |
| TOTAL RECOMMENDED | $39,515 | $6,225 |
$19,630
339,585
kWh
|
$2,065
-
kW-mo/yr
|
$17,820 | ||
| TOTAL IMPLEMENTED | $5,300 | $530 |
$4,300
75,360
kWh
|
$1,000
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs