Assessment Year | 2016 |
---|---|
Principal Product | Can Liners, Drawstring Bags |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $50 M to 100M |
# of Employees | 40 |
Plant Area |
233,403
ft2
|
Annual Production | 52,389,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $94,445 | 1,577,177 |
kWh
|
$0.060 |
Electricity Demand | $26,630 | 4,306 |
kW-mo/yr
|
$6.18 |
Electricity Fees | $3,377 | - |
|
- |
Natural Gas | $31,159 | 5,882 |
MMBtu
|
$5.30 |
LPG | $15,462 | 753 |
MMBtu
|
$20.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $46,312 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,854 | $42,330 |
$12,988
216,836
kWh
|
$3,866
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $12,472 | $8,000 |
$(-2,990.0)
(-49,920)
kWh
|
- | - |
$15,462
-
MMBtu
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $8,451 | $20,000 |
$247
4,117
kWh
|
$99
-
kW-mo/yr
|
$8,105
-
MMBtu
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $3,131 | $500 |
$2,413
40,285
kWh
|
$718
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,507 | $20 |
$1,981
34,155
kWh
|
$526
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,182 | $1,000 |
$758
12,649
kWh
|
$107
-
kW-mo/yr
|
- | - | $146 | $171 | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $971 | $800 |
$748
12,497
kWh
|
$223
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4133: Use most efficient type of electric motors | $744 | $2,450 |
$542
9,051
kWh
|
$202
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $46,312 | $75,100 |
$16,687
279,670
kWh
|
$5,741
-
kW-mo/yr
|
$8,105
-
MMBtu
|
$15,462
-
MMBtu
|
$146 | $171 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs