Assessment Year | 2002 |
---|---|
Principal Product | Refigeration and Heating Equipment |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
195,000
ft2
|
Annual Production | 1,068,365
pieces
|
Production Hrs. Annual | 3,544
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $300,202 | 6,465,588 |
kWh
|
$0.046 |
Electricity Demand | $16,089 | 7,806 |
kW-mo/yr
|
$2.06 |
Electricity Fees | $31,502 | - |
|
- |
Natural Gas | $109,839 | 17,176 |
MMBtu
|
$6.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $173,707 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $53,018 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $116,629 | $26,800 |
$53,818
1,240,037
kWh
|
- | - |
$62,811
-
MMBtu
|
|
02 | 2.6218: Turn off equipment when not in use | $14,100 | - |
$14,100
325,200
kWh
|
- | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $11,288 | - | - | - | $11,288 | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $6,890 | $620 |
$5,920
136,320
kWh
|
$970
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,290 | $1,200 |
$5,470
126,120
kWh
|
$820
-
kW-mo/yr
|
- | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $3,510 | $430 |
$2,560
59,000
kWh
|
$950
-
kW-mo/yr
|
- | - | |
07 | 2.6218: Turn off equipment when not in use | $3,810 | $605 |
$1,290
29,736
kWh
|
- | - |
$2,520
-
MMBtu
|
|
08 | 2.6218: Turn off equipment when not in use | $2,310 | - | - | - | - |
$2,310
-
MMBtu
|
|
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,030 | - |
$1,480
34,020
kWh
|
$550
-
kW-mo/yr
|
- | - | |
10 | 2.7124: Make a practice of turning off lights when not needed | $2,270 | - |
$2,270
52,200
kWh
|
- | - | - | |
11 | 2.6218: Turn off equipment when not in use | $1,500 | - |
$1,500
34,490
kWh
|
- | - | - | |
12 | 2.7135: Install occupancy sensors | $1,050 | $406 |
$1,050
24,195
kWh
|
- | - | - | |
13 | 2.2511: Insulate bare equipment | $895 | $225 | - | - | - |
$895
-
MMBtu
|
|
14 | 2.7111: Reduce illumination to minimum necessary levels | $610 | $180 |
$440
10,290
kWh
|
$170
-
kW-mo/yr
|
- | - | |
15 | 2.2136: Install / repair insulation on steam lines | $330 | $120 | - | - | - |
$330
-
MMBtu
|
|
16 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $195 | $120 |
$170
3,925
kWh
|
$25
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $173,707 | $30,706 |
$90,068
2,075,533
kWh
|
$3,485
-
kW-mo/yr
|
$11,288 |
$68,866
-
MMBtu
|
||
TOTAL IMPLEMENTED | $53,018 | $3,261 |
$34,160
787,261
kWh
|
$2,740
-
kW-mo/yr
|
$11,288 |
$4,830
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs