Assessment Year | 2002 |
---|---|
Principal Product | Commercial&Military Machined Parts |
NAICS |
n/a
|
SIC | 3496: Miscellaneous Fabricated Wire Products |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
70,000
ft2
|
Annual Production | 50,233
pieces
|
Production Hrs. Annual | 5,838
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $251,259 | 3,712,025 |
kWh
|
$0.068 |
Electricity Demand | $58,967 | 7,788 |
kW-mo/yr
|
$7.57 |
Electricity Fees | $16,315 | - |
|
- |
Natural Gas | $759 | 94 |
MMBtu
|
$8.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,525 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,545 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.3132: Use reverse osmosis to concentrate material | $10,025 | - | - | - | - |
$10,025
-
Tgal
|
- | |
02 | 2.8112: Combine utility meters | $7,040 | $13,000 | - | - | $7,040 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,040 | $400 |
$3,850
130,650
kWh
|
$3,190
-
kW-mo/yr
|
- | - | - | |
04 | 2.7442: Keep doors and windows shut when not on use | $2,600 | - |
$2,600
88,700
kWh
|
- | - | - | - | |
05 | 2.4314: Use synthetic lubricant | $1,920 | - |
$1,000
33,910
kWh
|
$920
-
kW-mo/yr
|
- | - | - | |
06 | 3.5316: Contract a wood pallet recycling company | $1,740 | - | - | - | - | - |
$1,740
-
gal
|
|
07 | 2.7122: Disconnect ballasts | $1,360 | $120 |
$745
25,220
kWh
|
$615
-
kW-mo/yr
|
- | - | - | |
08 | 2.8123: Pay utility bills on time | $1,220 | - | - | - | $1,220 | - | - | |
09 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $580 | - |
$580
19,750
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $33,525 | $13,520 |
$8,775
298,230
kWh
|
$4,725
-
kW-mo/yr
|
$8,260 |
$10,025
-
Tgal
|
$1,740
-
gal
|
||
TOTAL IMPLEMENTED | $24,545 | $400 |
$7,450
253,260
kWh
|
$4,110
-
kW-mo/yr
|
$1,220 |
$10,025
-
Tgal
|
$1,740
-
gal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs