| Assessment Year | 2026 |
|---|---|
| Principal Product | Frozen pasta |
| NAICS | 311412: Frozen Specialty Food Manufacturing |
| SIC | 2098: Macaroni, Spaghetti, Vermicelli, and Noodles |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
60,000
ft2
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 4,368
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $144,519 | 2,127,803 |
kWh
|
$0.068 | |
| Electricity Demand | $116,888 | 7,217 |
kW-mo/yr
|
$16.20 | |
| Electricity Fees | $28,691 | - |
|
- | |
| Natural Gas | $84,735 | 13,346 |
MMBtu
|
$6.35 | |
| Waste Disposal Costs | |||||
| Water Usage | $8,500 | 2,055 |
Tgal
|
$4.14 | |
| TOTAL YEARLY COSTS | $383,334 | ||||
| RECOMMENDED SAVINGS* | $18,616 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,844 | - | - |
$5,844
-
kW-mo/yr
|
- | - | |
| 02 | 3.1161: Eliminate/reduce an operation | $51 | - |
$225
3,315
kWh
|
$106
-
kW-mo/yr
|
$(-281.3)
-
MMBtu
|
- | |
| 03 | 2.7224: Reduce space conditioning during non-working hours | $9,917 | $200 |
$3,468
51,005
kWh
|
- |
$6,448
-
MMBtu
|
- | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $404 | $303 |
$185
2,716
kWh
|
$60
-
kW-mo/yr
|
- | $159 | |
| 05 | 2.2136: Install / repair insulation on steam lines | $266 | $408 | - | - |
$266
-
MMBtu
|
- | |
| 06 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $801 | $1,268 |
$801
11,773
kWh
|
- | - | - | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $104 | $187 |
$104
1,529
kWh
|
- | - | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,230 | $4,746 | - | - |
$1,230
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $18,616 | $7,112 |
$4,783
70,338
kWh
|
$6,011
-
kW-mo/yr
|
$7,663
-
MMBtu
|
$159 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs