Assessment Year 2026
Principal Product Frozen pasta
NAICS 311412: Frozen Specialty Food Manufacturing
SIC 2098: Macaroni, Spaghetti, Vermicelli, and Noodles
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 60,000
ft2
Annual Production 15,000,000
lb
Production Hrs. Annual 4,368
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $144,519 2,127,803
kWh
Electricity Demand $116,888 7,217
kW-mo/yr
Electricity Fees $28,691 -
Natural Gas $84,735 13,346
MMBtu
Waste Disposal Costs
Water Usage $8,500 2,055
Tgal
TOTAL YEARLY COSTS $383,334
RECOMMENDED SAVINGS* $18,616 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.3131: Reschedule plant operations or reduce load to avoid peaks $5,844 - - $5,844
-
kW-mo/yr
- -
02 3.1161: Eliminate/reduce an operation $51 - $225
3,315
kWh
$106
-
kW-mo/yr
$(-281.3)
-
MMBtu
-
03 2.7224: Reduce space conditioning during non-working hours $9,917 $200 $3,468
51,005
kWh
- $6,448
-
MMBtu
-
04 2.4322: Use or replace with energy efficient substitutes $404 $303 $185
2,716
kWh
$60
-
kW-mo/yr
- $159
05 2.2136: Install / repair insulation on steam lines $266 $408 - - $266
-
MMBtu
-
06 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $801 $1,268 $801
11,773
kWh
- - -
07 2.6211: Conserve energy by efficient use of vending machines $104 $187 $104
1,529
kWh
- - -
08 2.7447: Install vinyl strip / high speed / air curtain doors $1,230 $4,746 - - $1,230
-
MMBtu
-
TOTAL RECOMMENDED $18,616 $7,112 $4,783
70,338
kWh
$6,011
-
kW-mo/yr
$7,663
-
MMBtu
$159
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs