Assessment Year 2026
Principal Product Aerospace and Defense products
NAICS 334511: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufactur
SIC 3761: Guided Missiles and Space Vehicles
Sales Range greater than $500
M
# of Employees 2,794
Plant Area 1,496,782
ft2
Annual Production 20
units
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,576,593 22,935,772
kWh
Electricity Demand $573,127 44,256
kW-mo/yr
Electricity Fees $125,533 -
Natural Gas $526,022 93,907
MMBtu
Other Gas $5,507 1
MMBtu
Waste Disposal Costs
Water Usage $57,775 14,700
Tgal
TOTAL YEARLY COSTS $2,864,557
RECOMMENDED SAVINGS* $333,086 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,426 - $1,426
20,664
kWh
- - -
02 3.1161: Eliminate/reduce an operation $39,205 $682 $20,452
296,400
kWh
$25,835
-
kW-mo/yr
- $(-7,081.8)
-
MMBtu
03 2.2136: Install / repair insulation on steam lines $2,106 $566 - - - $2,106
-
MMBtu
04 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $5,185 $1,534 $5,185
75,142
kWh
- - -
05 2.2136: Install / repair insulation on steam lines $671 $329 $590
8,550
kWh
- - $81
-
MMBtu
06 2.4221: Install compressor air intakes in coolest locations $1,079 $1,860 $1,079
15,638
kWh
- - -
07 2.6211: Conserve energy by efficient use of vending machines $3,195 $5,578 $3,195
46,298
kWh
- - -
08 2.2625: Chill water to the highest temperature possible $79 $143 $79
1,149
kWh
- - -
09 2.7232: Replace existing hvac unit with high efficiency model $11,060 $26,128 $5,310
76,960
kWh
$5,750
-
kW-mo/yr
- -
10 2.4322: Use or replace with energy efficient substitutes $21,494 $143,758 $21,494
311,501
kWh
- - -
11 2.9114: Use solar heat to make electricty $247,587 $4,721,768 $177,587
2,573,732
kWh
- $70,000 -
TOTAL RECOMMENDED $333,086 $4,902,345 $236,396
3,426,034
kWh
$31,585
-
kW-mo/yr
$70,000 $(-4,894.6)
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs