| Assessment Year | 2026 |
|---|---|
| Principal Product | Inspection Molding/ Compounding |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 93 |
| Plant Area |
190,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $313,943 | 5,030,189 |
kWh
|
$0.062 |
| Electricity Demand | $60,817 | 21,594 |
kW-mo/yr
|
$2.82 |
| Electricity Fees | $32,724 | - |
|
- |
| Natural Gas | $20,444 | 3,692 |
MMBtu
|
$5.54 |
| Other Gas | $3,340 | 1 |
MMBtu
|
$3,339.65 |
| TOTAL YEARLY COSTS | $431,268 | |||
| RECOMMENDED SAVINGS* | $267,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $1,330 | $30 | - | - | - | - | $1,330 | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $1,332 | - |
$1,332
21,486
kWh
|
- | - | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $936 | $40 |
$936
15,092
kWh
|
- | - | - | - | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $515 | $38 |
$593
9,563
kWh
|
$148
-
kW-mo/yr
|
$(-225.8)
-
MMBtu
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $945 | $886 |
$687
11,082
kWh
|
$60
-
kW-mo/yr
|
- | - | $198 | |
| 06 | 2.4322: Use or replace with energy efficient substitutes | $261 | $392 |
$130
2,103
kWh
|
$8
-
kW-mo/yr
|
- | - | $122 | |
| 07 | 2.2136: Install / repair insulation on steam lines | $562 | $1,047 |
$562
9,071
kWh
|
- | - | - | - | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $171 | $520 |
$171
2,759
kWh
|
- | - | - | - | |
| 09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $225 | $792 | - | - |
$225
-
MMBtu
|
- | - | |
| 10 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $62,519 | $375,000 |
$(-18,481.0)
(-298,080)
kWh
|
- | - |
$81,000
-
MMBtu
|
- | |
| 11 | 2.7234: Use heat pump for space conditioning | $3,862 | $15,792 |
$(-236.4)
(-3,813)
kWh
|
- |
$4,099
-
MMBtu
|
- | - | |
| 12 | 2.9114: Use solar heat to make electricty | $194,971 | $2,475,576 |
$194,971
3,144,696
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $267,628 | $2,870,111 |
$180,665
2,913,959
kWh
|
$216
-
kW-mo/yr
|
$4,098
-
MMBtu
|
$81,000
-
MMBtu
|
$1,649 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs