| Assessment Year | 2026 |
|---|---|
| Principal Product | Precision optics |
| NAICS | 333310: Commercial and Service Industry Machinery Manufacturing |
| SIC | 3827: Optical Instruments and Lenses |
| Sales Range | $50 M to 100M |
| # of Employees | 450 |
| Plant Area |
151,356
ft2
|
| Annual Production | 65,000
units
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $685,305 | 5,155,107 |
kWh
|
$0.13 | |
| Electricity Demand | $374,085 | 21,123 |
kW-mo/yr
|
$17.71 | |
| Electricity Fees | $22,539 | - |
|
- | |
| Natural Gas | $52,195 | 10,079 |
MMBtu
|
$5.18 | |
| Other Gas | $734 | 10,079 |
MMBtu
|
$0.073 | |
| Waste Disposal Costs | |||||
| Water Usage | $20,000 | 2,931 |
Tgal
|
$6.82 | |
| TOTAL YEARLY COSTS | $1,154,858 | ||||
| RECOMMENDED SAVINGS* | $307,742 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $18,704 | - | - |
$18,704
-
kW-mo/yr
|
- | - | |
| 02 | 2.7122: Disconnect ballasts | $3,513 | - |
$2,835
21,314
kWh
|
$678
-
kW-mo/yr
|
- | - | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $37,179 | - |
$37,179
279,538
kWh
|
- | - | - | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $4,120 | $313 |
$2,394
18,000
kWh
|
$1,328
-
kW-mo/yr
|
$398
-
MMBtu
|
- | |
| 05 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $37,186 | $3,500 |
$37,186
279,596
kWh
|
- | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $41,161 | $16,667 |
$23,206
174,484
kWh
|
$9,298
-
kW-mo/yr
|
- | $8,657 | |
| 07 | 2.7135: Install occupancy sensors | $2,093 | $1,943 |
$2,093
15,739
kWh
|
- | - | - | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $1,631 | $1,642 |
$1,631
12,264
kWh
|
- | - | - | |
| 09 | 2.4322: Use or replace with energy efficient substitutes | $975 | $1,642 |
$616
4,635
kWh
|
$132
-
kW-mo/yr
|
- | $227 | |
| 10 | 4.631: Install an uninteruptable power supply | $160,000 | $480,000 | - | - | - | $160,000 | |
| 11 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,043 | $3,573 | - | - |
$1,043
-
MMBtu
|
- | |
| 12 | 2.2511: Insulate bare equipment | $50 | $185 |
$57
430
kWh
|
- |
$(-7.6)
-
MMBtu
|
- | |
| 13 | 2.2122: Install / repair insulation on condensate lines | $17 | $68 |
$15
116
kWh
|
- |
$2
-
MMBtu
|
- | |
| 14 | 2.2511: Insulate bare equipment | $69 | $384 | - | - |
$69
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $307,742 | $509,917 |
$107,213
806,115
kWh
|
$30,140
-
kW-mo/yr
|
$1,505
-
MMBtu
|
$168,884 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs