| Assessment Year | 2025 |
|---|---|
| Principal Product | Cider and bottling pasteurizing, process cleaning |
| NAICS | 445299: All Other Specialty Food Stores |
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
165,000
ft2
|
| Annual Production | 7,000,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $200,490 | 5,208,487 |
kWh
|
$0.038 |
| Electricity Demand | $319,530 | 11,616 |
kW-mo/yr
|
$27.51 |
| Electricity Fees | $11,711 | - |
|
- |
| Natural Gas | $417,833 | 79,128 |
MMBtu
|
$5.28 |
| LPG | $5,288 | 2,931 |
MMBtu
|
$1.80 |
| Other Gas | $10,699 | 1 |
MMBtu
|
$10,699.18 |
| TOTAL YEARLY COSTS | $965,551 | |||
| RECOMMENDED SAVINGS* | $122,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $15,976 | - | - |
$15,976
-
kW-mo/yr
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,743 | - |
$4,743
124,822
kWh
|
- | - | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $472 | $18 |
$145
3,825
kWh
|
$413
-
kW-mo/yr
|
$(-86.1)
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,295 | $125 |
$1,295
34,075
kWh
|
- | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $2,825 | $372 |
$2,825
74,346
kWh
|
- | - | - | |
| 06 | 2.2511: Insulate bare equipment | $1,088 | $728 | - | - |
$1,088
-
MMBtu
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,941 | $17,246 |
$1,629
42,873
kWh
|
$2,062
-
kW-mo/yr
|
- | $20,250 | |
| 08 | 2.2135: Repair and eliminate steam leaks | $3,215 | $2,800 | - | - |
$3,215
-
MMBtu
|
- | |
| 09 | 2.4322: Use or replace with energy efficient substitutes | $287 | $403 |
$80
2,102
kWh
|
$79
-
kW-mo/yr
|
- | $128 | |
| 10 | 2.6211: Conserve energy by efficient use of vending machines | $221 | $899 |
$221
5,825
kWh
|
- | - | - | |
| 11 | 4.631: Install an uninteruptable power supply | $35,256 | $160,000 | - | - | - | $35,256 | |
| 12 | 2.9114: Use solar heat to make electricty | $32,946 | $668,352 |
$32,946
867,000
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $122,265 | $850,943 |
$43,885
1,154,868
kWh
|
$18,530
-
kW-mo/yr
|
$4,217
-
MMBtu
|
$55,634 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs