ITAC Assessment: SU0563
ITAC logo
ITAC Assessment: SU0563
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Plastic bottles and plates used in life sciences
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 212
Plant Area 134,000
ft2
Annual Production 84,746,000
units
Production Hrs. Annual 4,992
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $420,741 13,116,451
kWh
Electricity Demand $285,648 29,694
kW-mo/yr
Electricity Fees $250,397 -
Natural Gas $15,303 2,492
MMBtu
Other Gas $5,134 1
MMBtu
Waste Disposal Costs
Water Usage $22,728 1,437
Tgal
Water Disposal $11,347 1,437
Tgal
TOTAL YEARLY COSTS $1,011,297
RECOMMENDED SAVINGS* $164,924 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4239: Eliminate or reduce compressed air usage $6,490 - $6,490
202,818
kWh
- - -
02 2.3131: Reschedule plant operations or reduce load to avoid peaks $14,283 - - $14,283
-
kW-mo/yr
- -
03 2.4322: Use or replace with energy efficient substitutes $488 $40 $306
9,563
kWh
$433
-
kW-mo/yr
$(-250.5)
-
MMBtu
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,699 $660 $3,699
115,607
kWh
- - -
05 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $2,466 $1,340 $2,466
77,071
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $26,793 $40,140 $17,811
556,602
kWh
$7,350
-
kW-mo/yr
- $1,631
07 2.4322: Use or replace with energy efficient substitutes $1,332 $2,425 $404
12,615
kWh
$166
-
kW-mo/yr
- $762
08 2.7447: Install vinyl strip / high speed / air curtain doors $328 $1,597 - - $328
-
MMBtu
-
09 2.2622: Replace existing chiller with high efficiency model $40,498 $249,040 $40,498
1,265,562
kWh
- - -
10 2.7234: Use heat pump for space conditioning $10,607 $70,800 $(-4,696.5)
(-146,765)
kWh
- $15,303
-
MMBtu
-
11 2.9114: Use solar heat to make electricty $57,940 $773,422 $57,940
1,810,624
kWh
- - -
TOTAL RECOMMENDED $164,924 $1,139,464 $124,918
3,903,697
kWh
$22,232
-
kW-mo/yr
$15,381
-
MMBtu
$2,393
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs