| Assessment Year | 2024 |
|---|---|
| Principal Product | Plastic bottles and plates used in life sciences |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 212 |
| Plant Area |
134,000
ft2
|
| Annual Production | 84,746,000
units
|
| Production Hrs. Annual | 4,992
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $420,741 | 13,116,451 |
kWh
|
$0.032 | |
| Electricity Demand | $285,648 | 29,694 |
kW-mo/yr
|
$9.62 | |
| Electricity Fees | $250,397 | - |
|
- | |
| Natural Gas | $15,303 | 2,492 |
MMBtu
|
$6.14 | |
| Other Gas | $5,134 | 1 |
MMBtu
|
$5,133.89 | |
| Waste Disposal Costs | |||||
| Water Usage | $22,728 | 1,437 |
Tgal
|
$15.82 | |
| Water Disposal | $11,347 | 1,437 |
Tgal
|
$7.90 | |
| TOTAL YEARLY COSTS | $1,011,297 | ||||
| RECOMMENDED SAVINGS* | $164,924 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $39,448 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $6,490 | - |
$6,490
202,818
kWh
|
- | - | - | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $14,283 | - | - |
$14,283
-
kW-mo/yr
|
- | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $488 | $40 |
$306
9,563
kWh
|
$433
-
kW-mo/yr
|
$(-250.5)
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,699 | $2,100 |
$3,699
115,607
kWh
|
- | - | - | |
| 05 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $2,466 | $500 |
$2,466
77,071
kWh
|
- | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26,793 | $26,262 |
$17,811
556,602
kWh
|
$7,350
-
kW-mo/yr
|
- | $1,631 | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $1,332 | $2,425 |
$404
12,615
kWh
|
$166
-
kW-mo/yr
|
- | $762 | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $328 | $1,597 | - | - |
$328
-
MMBtu
|
- | |
| 09 | 2.2622: Replace existing chiller with high efficiency model | $40,498 | $1,249,040 |
$40,498
1,265,562
kWh
|
- | - | - | |
| 10 | 2.7234: Use heat pump for space conditioning | $10,607 | $70,800 |
$(-4,696.5)
(-146,765)
kWh
|
- |
$15,303
-
MMBtu
|
- | |
| 11 | 2.9114: Use solar heat to make electricty | $57,940 | $773,422 |
$57,940
1,810,624
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $164,924 | $2,126,186 |
$124,918
3,903,697
kWh
|
$22,232
-
kW-mo/yr
|
$15,381
-
MMBtu
|
$2,393 | ||
| TOTAL IMPLEMENTED | $39,448 | $28,862 |
$30,467
952,098
kWh
|
$7,350
-
kW-mo/yr
|
- | $1,631 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs