Assessment Year 2016
Principal Product Medical Carts & Electronic Enclosures
NAICS 332322: Sheet Metal Work Manufacturing
SIC 3444: Sheet Metal Work
Sales Range $10
M
to 50
M
# of Employees 121
Plant Area 150,000
ft2
Annual Production 194,963
units
Production Hrs. Annual 4,080
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $153,256 2,120,539
kWh
Electricity Demand $91,649 7,203
kW-mo/yr
Electricity Fees $4,010 -
Natural Gas $68,726 20,511
MMBtu
TOTAL YEARLY COSTS $317,641
RECOMMENDED SAVINGS* $32,042 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,051

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $12,568 $2,860 - - $12,568
-
MMBtu
-
02 2.8112: Combine utility meters $8,777 $30,000 - - - $8,777
03 2.7135: Install occupancy sensors $2,746 $1,275 $2,746
38,385
kWh
- - -
04 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $2,722 - $2,722
38,052
kWh
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,051 $230 $1,351
18,887
kWh
$700
-
kW-mo/yr
- -
06 2.4221: Install compressor air intakes in coolest locations $1,795 $1,501 $877
12,265
kWh
$917
-
kW-mo/yr
- -
07 2.7134: Use photocell controls $1,383 $560 $899
12,659
kWh
$484
-
kW-mo/yr
- -
TOTAL RECOMMENDED $32,042 $36,426 $8,596
120,248
kWh
$2,101
-
kW-mo/yr
$12,568
-
MMBtu
$8,777
TOTAL IMPLEMENTED $2,051 $230 $1,351
18,887
kWh
$700
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs